Series name | Method | Battery type | Features | Capacity range | Expected life (Approx.) |
Major application |
---|---|---|---|---|---|---|
Vent type (Catalyst plug vent type) |
Lead | Standard | 15 to 2400Ah |
10 to 14 years |
Communication Switching equipments Electric power equipment operation All other floating charge system |
|
Vent type (Catalyst plug vent type) |
Lead | High-rate discharging |
30 to 2500Ah |
5 to 7 years |
UPS (Large and Medium capacity) Engine starting Instrumentation All other floating charge system |
|
Vent type (Catalyst plug vent type) |
Lead | Standard | 190 to 1980Ah |
7 to 12 years |
Communication Equipment operation All other floating charge system |
Series name | Method | Battery type | Features | Capacity range | Expected life (Approx.) |
Major application |
---|---|---|---|---|---|---|
Valve regulated type | Lead | Standard | 30 to 100Ah | 5 to 7 years(Note) |
Communication Switching equipments Emergency lighting Automatic control All other floating charge system |
|
Valve regulated type | Lead | Standard | 50 to 3000Ah | 7 to 9 years(Note) |
Communication Switching equipments Electric power equipment operation All other floating charge system |
|
Valve regulated type | Lead | Long life | 50 to 3000Ah | 13 to 15 years(Note) | Communication Switching equipments Electric power equipment operation All other floating charge system |
|
Valve regulated type | Lead | Long life Space saving |
500 to 3000Ah | 13 to 15 years(Note) | Communication Switching equipments Electric power equipment operation All other floating charge system |
|
Valve regulated type | Lead | High-rate discharging | 50,200,300Ah | 7 to 9 years(Note) |
UPS | |
Mono-block Space saving |
100, 150Ah |
(Note) Float life (Trickle life) evaluation temperature/ discharge current:
MSE・FVL・FMU-S・HSE→25℃/0.1C10A
FVH→25℃/3.3C10A
Expected life varies depending on usage condition (such as temperature, discharge rate), and the numeric value is not guaranteed.
“Expected life” is a lifetime assuming certain conditions and maintenance management.
Here, the “expected life” can be expected in the case of the ambient temperature is 25℃, suitable floating charge voltage and number of discharge is several times a year, therefore it does not guarantee the years in actual use.
Series name | Method | Battery type | Features | Capacity range | Expected life (Approx.) (Note4) |
Major application |
---|---|---|---|---|---|---|
Valve regulated type | Lead | Standard | 12V 2 to 38Ah, 6V 10Ah |
3 years (Note1) Approx. 200 times (Note3) |
Standby use
Cycle use
|
|
Valve regulated type | Lead | Long life | 12V 0.8 to 17Ah |
6 years (Note1) |
||
Valve regulated type | Lead | Ultra-long life | 12V 2 to 65Ah | 13 years (Note1) |
||
Valve regulated type | Lead | High-rate discharging Long life |
12V 5.5 to 8.8Ah |
3 years (Note2) |
UPS and other use | |
12V 10 to 38Ah |
5 years (Note2) |
(Standby use)
(Note1)A trickle life in the case of 25℃ constant, obtained from a high temperature accelerated test. The capacity test: 0.25C20A, Life determination: 50% of the rated capacity (20HR)
(Note2) A trickle life in the case of 30℃ constant, obtained from a high temperature accelerated test. Capacity test: 3C20A, Life determination: 3min. of sustained period.
Here, C20 shows a numeric value of 20 hrs rated capacity.
(Cycle use)
(Note3)Test temperature: 25℃, Discharge: 0.25C20A, Discharge stop voltage: 1.7V/cell, Charge: 2.45 V/cell constant voltage charge, Charge amount: 110%, Life determination: 50% of rated capacity (20HR), Cycle life of all the m series, FML series and FHL series are the same. Note that FPX series is incompatible with the cycle use.
Here, C20 shows a numeric value of 20 hrs rated capacity.
(Note4) “Expected life” is a life assuming certain conditions and maintenance management. The battery life in actual use varies with usage conditions (such as ambient temperature, discharge frequency, discharge rate and charge condition) and use history. Therefore the “expected life” does not guarantee the years of actual use.
Series name | Method | Battery type | Features | Capacity range | Expected life25℃, DOD70%(Approx.) | Major application |
---|---|---|---|---|---|---|
FCP | Valve regulated type | Lead | Cycle use | 500,1000Ah | 4500 cycles (Note) |
|
UB | Valve regulated type | Lead | Cycle use | 1000Ah | 4500 cycles (Note) |
|
(Note) “Expected life” is based on our recommended condition of use, and is different from a guaranteed value.
Series name | Method | Battery type | Features | Capacity range |
Expected life (Approx.) |
Major application |
---|---|---|---|---|---|---|
Seal type | Alkaline sintered |
Ultra-high-rate discharging |
10 to 400Ah | 12 to 15 years |
Equipment operation Instrumentation Control Emergency lighting |
|
Liquid type | Alkaline sintered |
Ultra-high-rate discharging |
20 to 1000Ah | 12 to 15 years |
UPS Engine starting Emergency lighting Equipment operation |
|
Liquid type | Alkaline sintered |
High-rate discharging |
20 to 1200Ah | 12 to 15 years |
UPS Equipment operation Instrumentation Control Emergency lighting |
|
Liquid type | Alkaline |
Ultra-high-rate discharging |
20 to 450Ah | 12 to 15 years |
UPS Engine starting Emergency lighting Equipment operation |
|
Liquid type | Alkaline |
High-rate discharging |
20 to 700Ah | 12 to 15 years |
UPS Equipment operation Instrumentation Control Emergency lighting |
|
Liquid type | Alkaline |
Intermediate of the High rate and standard discharge |
20 to 1000Ah | 12 to 15 years |
Emergency lighting Operation Instrumentation Control |
|
Liquid type | Alkaline |
Standard discharge | 20 to 1000Ah | 12 to 15 years |
Emergency lighting Operation Communication Instrumentation Control |
Series name | Method | Battery type | Features | Capacity range | Expected life | Major application |
---|---|---|---|---|---|---|
Seal type | Alkali | High durability |
100 to 10,000mAh |
Depends on use | Disaster prevention equipment Business equipment Measuring equipment Others |
- Open PDFBattery Condition Watcher (4,045KB)
Battery Condition Watcher (BCW) is installed in the vicinity of the storage battery, and measures voltage, internal resistance and temperature of individual battery. The measured data are obtained by a system controller (BCWT4) through the wireless communication between BCWHub. Two Hubs can be connected to one BCWT4 and 128 BCWs can be connected in maximum. In the case of the more BCWs are necessary, this combination is added more.